Plants 2, 4 & 5 Solar PV Design and Construct
Tender Overview
About this tender
Overview Busselton Water is seeking a suitably qualified renewable energy contractor to design, supply, install, test, commission and hand over new solar photovoltaic systems at Plants 2, 4 and 5. Scope The scope includes: Design, supply, installation, testing, commissioning and handover of roof-mounted solar PV systems at Plants 2 and 4 Design, supply, installation, testing, commissioning and handover of a ground-mounted solar PV system at Plant 5 Associated electrical, structural, civil, monitoring, approval and handover activities Verifying, developing and completing the remaining design to 100% construction-ready status, including all calculations, details, coordination, approvals and documentation required to deliver complete and compliant systems Submission of design documentation and calculations to Busselton Water for review before procurement, fabrication or installation Testing and commissioning, receipt of required authority approvals, rectification of defects, provision of training, warranties, test and commissioning records, as-constructed drawings, operation and maintenance manuals and other handover deliverables Plant 2: approximately 130 kWdc/100 kWac of new roof-mounted solar PV, replacement of the existing SMA inverters, reconfiguration of the existing PV strings, and a combined system of approximately 229.6 kWdc/200 kWac Plant 4: approximately 100 kWdc/80 kWac of new roof-mounted solar PV Plant 5: approximately 100 kWdc/80 kWac of new ground-mounted solar PV, including a replacement Site Main Switchboard and coordination with Western Power under reference SP053420 Provision of hybrid inverter, export prevention, monitoring and battery-ready infrastructure at each site Separate pricing of a Battery Energy Storage System option at each site, which is excluded from the base Works Contractor Requirements Suitably qualified renewable energy contractor capable of designing, supplying, installing, testing, commissioning and handing over the Works The Contractor remains fully responsible for the completed design, constructability, compliance and performance of the Works, notwithstanding review of design documentation by Busselton Water Instructions to Tenderers The detailed scope, design criteria, equipment requirements, drawings, standards, deliverables, programme, commissioning, training, maintenance and tender pricing requirements are set out in the Busselton Water – Plants 2, 4 & 5 Solar PV Design & Construct Brief (DC Brief), Project Ref. ENPER25041, Revision 1, dated 3 July 2026. The DC Brief and its referenced drawings form the principal technical requirements for the Works and are to be read together with Part F and the remaining Contract documents. The DC Brief and referenced drawings represent an approximately 80% developed design and are provided as the basis for tendering. Tenderers shall allow for all work necessary to provide complete, compliant and operational systems, whether expressly stated in Part F or reasonably required by the DC Brief, the drawings, applicable standards, authority requirements and the proposed design. Part F provides the contractual overview only and does not reproduce the detailed technical requirements contained in the DC Brief.
How to respond to this tender
A strong tender response is clear, compliant, and backed by evidence. These steps apply to most Australian and New Zealand public tenders.
Read the requirements in full
Open the official listing and download the full tender pack. Note the response schedules, evaluation criteria, mandatory conditions, and the exact closing time and lodgement method.
Confirm you are eligible and it is worth bidding
Check licences, insurances, certifications, and any conformance requirements before you commit. A quick bid or no-bid decision saves days of wasted effort on a tender you cannot win.
Answer every criterion with evidence
Respond to each evaluation criterion directly and back your claims with concrete examples, referees, and past performance. Address the buyer’s stated need, not a generic capability statement.
Lodge early through the official portal
Submit through the source portal well before the deadline. Late or incorrectly lodged bids are almost always rejected, so leave time for uploads, portal errors, and last-minute questions.