Tully Water Main Renewals (Bamber, Kirk, Dowzer, Bryant Streets)

Closes in 25 daysClose date: 7 September 2026

About this tender

Overview Cassowary Coast Regional Council is seeking a contractor to supply and install water main renewals in Tully, covering Bamber Street, Kirk Street, Dowzer Street, and Bryant Street. Scope The scope includes supply and installation of water mains complete, including excavation, bedding, backfill, special pipes, fittings and thrust blocks for the following works: Bamber Street (WM01) Supply and installation of approximately 428m of open Type C trenched DN150 PVC-M RRJ PN16 water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) Supply and installation of approximately 22m of open Type M-1_CCRC trenched DN150 PN35 DICL water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) 12 Property Connections, 20mm ID Chorblue POLY Class 20, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape and Cadia Part No. 69562 toby boxes with DN100 PVC riser at ferrules (no road crossing) 10 Property Connections, 20mm ID Chorblue POLY Class 20 including Cadia Part No. 69562 toby boxes, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape (road crossing) Supply and installation of 5 spring hydrants complete, including chamber, cover box, margin sets and marker, for 150mm dia mains (excludes FH's in valve cluster details) Dowzer Street (WM02) Supply and installation of approximately 236m of open Type C trenched DN150 PVC-M water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) Supply and installation of approximately 118m of open Type M-1_CCRC trenched DN150 PN35 DICL water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) 5 Property Connections, 20mm ID Chorblue POLY Class 20, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape and Cadia Part No. 69562 toby boxes with DN100 PVC riser at ferrules (no road crossing) 9 Property Connections, 20mm ID Chorblue POLY Class 20 including Cadia Part No. 69562 toby boxes, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape (road crossing) Supply and installation of 4 spring hydrants complete, including chamber, cover box, margin sets and marker, for 150mm dia mains (excludes FH's in valve cluster details) Bryant Street (WM03) Supply and installation of approximately 343m of open Type C trenched DN150 PVC-M water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) Supply and installation of approximately 31m of open Type M-1_CCRC trenched DN150 PN35 DICL water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) 1 Property Connection, 20mm ID Chorblue POLY Class 20, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape and Cadia Part No. 69562 toby boxes with DN100 PVC riser at ferrules (no road crossing) 2 Property Connections, 20mm ID Chorblue POLY Class 20 including Cadia Part No. 69562 toby boxes, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape (road crossing) Supply and installation of 5 spring hydrants complete, including chamber, cover box, margin sets and marker, for 150mm dia mains (excludes FH's in valve cluster details) Kirk Street (WM04) Supply and installation of approximately 132m of open Type C trenched DN150 PVC-M water main, valves, hydrants, connections, thrust restraints, and fittings as specified (refer to Project Drawings, FNQROC SD S2016, CCRC Standard Drawings 15034-V1 to 15034-V7, and FNQROC Specification S5 for bedding and backfill requirements) 1 Property Connection, 20mm ID Chorblue POLY Class 20, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape and Cadia Part No. 69562 toby boxes with DN100 PVC riser at ferrules (no road crossing) 5 Property Connections, 20mm ID Chorblue POLY Class 20 including Cadia Part No. 69562 toby boxes, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape (road crossing) 2 dual service Property Connections, 25mm ID Chorblue POLY Class 20 common with DN100 PVC conduit and 2 x 20mm ID Chorblue POLY Class 20, supply pipes, sawcut, trench, lay, bed, joint, backfill, disinfection and resurface to lines and levels shown on construction drawings, including detector tape and Cadia Part No. 69562 toby boxes with DN100 PVC riser at ferrules (road crossing) Supply and installation of 1 spring hydrant complete, including chamber, cover box, margin sets and marker, for 150mm dia mains (excludes FH's in valve cluster details)

How to respond to this tender

A strong tender response is clear, compliant, and backed by evidence. These steps apply to most Australian and New Zealand public tenders.

Read the requirements in full

Open the official listing and download the full tender pack. Note the response schedules, evaluation criteria, mandatory conditions, and the exact closing time and lodgement method.

Confirm you are eligible and it is worth bidding

Check licences, insurances, certifications, and any conformance requirements before you commit. A quick bid or no-bid decision saves days of wasted effort on a tender you cannot win.

Answer every criterion with evidence

Respond to each evaluation criterion directly and back your claims with concrete examples, referees, and past performance. Address the buyer’s stated need, not a generic capability statement.

Lodge early through the official portal

Submit through the source portal well before the deadline. Late or incorrectly lodged bids are almost always rejected, so leave time for uploads, portal errors, and last-minute questions.

Ready to write winning tenders?

Sign up today, what a relief.

Sign up